Continuous Standby Power Rating Model #04917 30kW 60 Hz LPV
/ 27kW 60 Hz NG UL 2200 Listed Power Matched

| | INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these | | SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electroniy torque-matching the surge loads to the engine. |
| | systems will provide superior performance. TEST CRITERIA: >PROTOTYPE TESTED | | SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. You are never on your own when you own a GENERAC POWER SYSTEM. |
| >SYSTEM TORSIONAL TESTED >ELECTRO-MAGNETIC INTERFERENCE >NEMA MG1-22 EVALUATION | | GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. | |
| > MOTOR STARTING ABILITY |
Four pole, revolving field generator, directly connected to the engine shaft through a heavy-duty, flexible disc for permanent alignment.
Unit tested for motor starting ability by measuring instantaneous voltage dip with a wave form data acquisition system.
All models utilize an advanced wire harness design for reliable interconnection within the circuitry.
Magnetic circuit, including amortisseur windings, tooth and skewed stator design, provides a minimal level of waveform distortion and an electromagnetic interference level which meets accepted requirements for standard AM radio, TV, and marine radio telephone applications.
Voltage waveform deviation, total harmonic content of the AC waveform, and balanced T.I.F. (Telephone Influence Factor) have been evaluated to acceptable standards in accordance with NEMA MG1-22.
Alternator is self-ventiliated and of drip-proof guarded construction.
Fully life-tested protective systems, including “field circuit and thermal overload protection” and standard main line circuit breakers capable of handling full output capacity.
System torsional acceptability confirmed during prototype testing.
GENERATOR SPECIFICATIONS
TYPE ...................................................................... Four-pole, revolving field
ROTOR INSULATION ....................................................................... Class F
STATOR INSULATION ...................................................................... Class H
TOTAL HARMONIC DISTORTION (line to line) ................................. <3.5%
TELEPHONE INTERFERENCE FACTOR (TIF) ..................................... <50
ALTERNATOR ................................................. Self-ventilated and drip-proof
BEARINGS (PRE-LUBED & SEALED) ....................................................... 1
COUPLING .................................................................... Direct, Flexible Disc
LOAD CAPACITY (STANDBY) ............................................................. 100%
LOAD CAPACITY (PRIME) .................................................................. 110%
NOTE: Emergency loading in compliance with NFPA 99, NFPA 110,
paragraph 5-13.2.6. Generator rating and performance in accordance
with ISO8528-5, BS5514, SAE J1349, ISO3046, and DIN6271 standards.
EXCITATION SYSTEM
DIRECT .................................................................. DC excitation system ?
Low-velocity brushes and slip rings ?
VOLTAGE REGULATION ......................................................... Solid-state ?
±1% regulation ?
ENGINE SPECIFICATIONS
MAKE .......................................................................................... GENERAC
MODEL ............................................................................................... 3.0GN
CYLINDERS ...................................................................................... V-6 60°
DISPLACEMENT ........................................................ 3.0 Liter (182 cu. in.)
BORE ............................................................................... 88.9 mm (3.50 in.)
STROKE .......................................................................... 78.7 mm (3.10 in.)
COMPRESSION RATIO ........................................................................ 9.3:1
INTAKE AIR ................................................................... Naturally Aspirated
NUMBER OF MAIN BEARINGS ................................................................ 4
CONNECTING RODS .................................................... 6-Drop forged steel
CYLINDER HEAD .......................................................................... Cast Iron
PISTONS ................................................. 6-Notched Head, Aluminum Alloy
CRANKSHAFT ............................................................................... Cast Iron
VALVE TRAIN
LIFTER TYPE ...................................................................... Hydraulic Roller
INTAKE VALVE MATERIAL ..................................... Aluminized Steel Faced
EXHAUST VALVE MATERIAL .................................................... Steel Faced
HARDENED VALVE SEATS ..................................................................... No
ENGINE GOVERNOR
? ELECTRONIC.............................................................................. Standard
FREQUENCY REGULATION, NO-LOAD TO FULL LOAD ............ 0.5%
STEADY STATE REGULATION .................................................. ±0.25%
LUBRICATION SYSTEM
TYPE OF OIL PUMP ............................................................................ Gear
OIL FILTER ...................................................................... Full flow, cartridge
CRANKCASE CAPACITY ............................................. 4.73 Liters (5.0 qts.)
COOLING SYSTEM
TYPE OF SYSTEM ........................................ Pressurized, closed recovery
WATER PUMP .......................................................... Pre-lubed, self-sealing
TYPE OF FAN ............................................................ Variable speed clutch
NUMBER OF FAN BLADES ....................................................................... 7
DIAMETER OF FAN ............................................................ 432 mm (18 in.)
FUEL SYSTEM
FUEL
? Natural Gas or L.P. Vapor .......................................................... Standard
CARBURETOR ............................................................................ Side draft
SECONDARY FUEL REGULATOR ............ Nat. Gas or L.P. Vapor Systems
AUTOMATIC FUEL LOCKOFF SOLENOID ................................... Standard
OPERATING FUEL PRESSURE VAPOR SYSTEMS ..Nat. Gas 5 to 14” H2O
LP Vapor.....11” to 14” H2O
ELECTRICAL SYSTEM
BATTERY CHARGE ALTERNATOR ................................... 15 Amps at 12 V
STARTER MOTOR .................................................................................. 12 V
RECOMMENDED BATTERY ................................... (1) - 12 V, 90 A.H., 27F
GROUND POLARITY ..................................................................... Negative
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc.
Home Standby Generator 30 kW Operating Data
| STANDBY | ||||||
|---|---|---|---|---|---|---|
| GENERATOR OUTPUT VOLTAGE/KW - 60Hz | Home Standby - 30 | |||||
| LP | NG | Amps LP | Amps NG | |||
| 120/240V, 1-phase, 1.0 pf | 30 | 27 | 250/125 | 225/112.5 | ||
| MOTOR STARTING KVA Maximum at 35% instantaneous voltage dip | 45 | 40 | ||||
| Main Line Circuit Breaker | 150 Amp | |||||
| FUEL Fuel consumption - 60 Hz--100% Load ft.3 /hr.(gal./hr) m3 /hr. | LP | NG | ||||
| 160 (4.4) 4.5 | 387 10.96 | |||||
| COOLING | LP | NG | ||||
| Coolant capacity System lit.(US gal.) Coolant flow/min. 60 Hz lit.(US gal.) Heat rejection to coolant BTU/hr. Radiator air flow 60 Hz m3/min. (cfm) Max. operating air temperature onto radiator °F Max. operating ambient temperature °F | 122,000 | 11.36 (3.0) 67.76 (17.9) 107,500 119 (4200) 140 120 | ||||
| COMBUSTION AIR REQUIREMENTS | LP | NG | ||||
| Flow at rated power 60 Hz m3/min. (cfm) | 2.55 (90) | |||||
| EXHAUST | LP | NG | ||||
| Exhaust flow at rated output 60 Hz m3/min. (cfm) Max. recommended back pressure Kpa (Hg) Exhaust temp. at rated output °C (°F) | 7.4 (262) 5.0 (1.5”) 593 (1100) | 6.8 (240) 5.0 (1.5”) 566 (1050) | ||||
| ENGINE | LP | NG | ||||
| Rated at RPM 60 Hz HP at rated KW 60 Hz Piston speed 60 Hz m/sec. (ft./min.) BMEP 60 Hz | 49.7 4.7 (930) 119 | 1800 45 4.7 (930) 108 | ||||
| POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature -1.65% for every 10°F above - °F Altitude -3.0% for every 1000 ft. above - ft. | 77 600 | |||||
| SOUND OUTPUT In dB(A) at 23 feet with generator operating at full load | 71.8 | |||||
| TRANSFER SWITCH SPECIFICATIONS (Transfer switch is not included with this model) | ||||||
High Coolant Temperature Automatic Shutdown Battery Charge Alternator Low Coolant Level Automatic Shutdown Battery Cables Low Oil Pressure Automatic Shutdown Battery Tray Overspeed Automatic Shutdown (Solid-state) Vibration Isolation of Unit to Mounting Base Crank Limiter (Solid-state) 12 Volt, Solenoid-Activated Starter Motor Oil Drain Extension Air Cleaner Radiator Drain Extension Fan Guard Factory-Installed Cool Flow Radiator Control Console Closed Coolant Recovery System Stainless Steel Flexible Exhaust Connection UV/ Ozone Resistant Hoses Main Line Circuit Breaker Rubber-Booted Engine Electrical Connections Critical Exhaust Silencer Fuel Lockoff Solenoid Battery Trickle Charger Isochronous Governor All Aluminum Weather Protective Enclosure Secondary Fuel Regulator (N.G. and L.P.G.) (Locking Type)
Home Standby Control Features:
| Home Standby Control | Home Standby Microprocessor |
| Console | Controls |
| Manual/Auto/Off switch | Automatic voltage regulation |
| Six light LED indicator for | Utility voltage sensing |
| generator status and | Utility interrupt delay |
| fault status | (10-second setpoint) |
| Fuses (panel overload) | Engine warm-up |
| Set exercise time switch | (10-second setpoint) |
| Engine cool-down | |
| (1-minute setpoint) | |
| Seven-day exerciser |

Design and specifications subject to change without notice. Dimensions shown are approximate. Contact your Guardian dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
UNIT WEIGHT: 1250 lbs.
GENERAC POWERSYSTEMS - All specifications subject to change without notice.
Copyright 2006 Power Generators