INCLUDES:

| INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that theses ystems will provide superior performance. TEST CRITERIA: PROTOTYPE TESTED SYSTEM TORSIONAL TESTED NEMA MG1-22 EVALUATION MOTOR STARTING ABILITY | SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electroniy torque-matching the surge loads to the engine.
SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. You are never on your own when you own a GENERAC POWER SYSTEM. |
| GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility |
| ENGINE •Generac (OHVI) Design •”Spiny-lok” cast iron cylinder walls •Electronic ignition, spark advance and compression release •Full pressure lubrication system •Low oil pressure shutdown system •High temperature shutdown | Maximizes engine “breathing” for increased fuel efficiency. Cylinder walls run cooler, reducing oil consumption. Because heat is the primary cause of engine wear, the OHVI has a significantly longer life than competitive engines. Rigid construction and added durability provide long engine life. These features combine to assure smooth, quick starting every time. Superior lubrication to all vital bearings means better performance, less maintenance and significantly longer engine life. Superior shutdown protection prevents catastrophic engine damage due to low oil. Prevents damage due to overheating. | |
|---|---|---|
| GENERATOR | •Revolving field •Skewed stator •Displaced phase excitation •Automatic voltage regulation •UL 2200 Listed | Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Produces a smooth output waveform for compatibility with electronic equipment. Maximizes motor starting capability. Provides more surge capability than brushless generator designs. Regulates the output voltage to ±2% prevents damaging voltage spikes. For your safety |
| TRANSFERSWITCH | Not included with this model | |
| MICROPROCESSOR CONTROL | •Manual/Auto/Off switch •Utility voltage sensing •Utility interrupt delay •Engine warm-up •Engine cool-down •Seven day exerciser •Timed Trickle Battery charger •Main Line Circuit Breaker •Six LED status indicator lights | Selects the operating mode. Constantly monitors utility voltage, setpoints 60% dropout, 70% pick-up, of standard voltage. Prevents nuisance start-ups of the engine, set point approximately 10 seconds. Ensures engine is ready to assume the load, setpoint approximately 10 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Operates engine to prevent oil seal drying and damage between power outages. Maintains battery amperage to insure starting. Protects generator from overload. Allows monitoring of generator condition in the event of generator shutdown or system readiness. |
| UNIT | •Aluminum weather protective enclosure •Enclosed critical grade muffler •Small, compact, attractive •1’ Flexible Fuel Line •Composite Mounting Pad •UL Listed | Ensures protection against mother nature. Fights corrosion even in the most severe environments. Electrostatiy applied epoxy paint for added durability. Hinged key locking roof panel for security. Gas support lifts on roof panel for convenience. Engineered air-channeling design reduces sound output to level equal to that of normal conversation. Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation. For connection between rigid pipe and generator fuel inlet. Absorbs vibration during operation. Eliminates the need to pour a concrete base. For your safety and assurance of full rated power output. |
GENERATOR Model 04916 (11kW)
Rated Maximum Continuous Power Capacity (LPG)...................................................................................................... 11,000 Watts*
Rated Maximum Continuous Power Capacity (NG)......................................................................................................... 10,000 Watts*
Rated Voltage........................................................................................................................................................................120/240
Rated Maximum Continuous Load Current
120 Volts .................................................................................................................................................................................70.8
240 Volts ................................................................................................................................................................................ 35.4
Main Line Circuit Breaker .................................................................................................................................................... 50 Amp
Phase ........................................................................................................................................................................................1
Number of Rotor Poles ............................................................................................................................................................. 2
Rated AC Frequency ............................................................................................................................................................. 60Hz
Power Factor .............................................................................................................................................................................1
Battery Requirement (not included) ............................................................................................................................... Group 26/26R
12 Volts and
550 Cold-cranking
Amperes Minimum
Shipping Weight (Includes Transfer Switch) .............................................................................................................. Approx. 495 Pounds
Dimensions (L” x W” x H”)................................................................................................................................................ 48 x 39 x 31
Sound Output in dB(A) at 23 ft. with generator operating at full load .................................................................................... 62.2
ENGINE Model 04916 (11kW)
Type of Engine....................................................................................................................................................... GENERAC OHVI V-TWIN
Number of Cylinders.................................................................................................................................................................. 2
Rated Horsepower............................................................................................................................................................30 @3,600 rpm
Displacement......................................................................................................................................................................... 992cc
Cylinder Block.............................................................................................................................................................. Aluminum w/Cast
Iron Sleeve
Valve Arrangement........................................................................................................................................................ Overhead Valve
Ignition System........................................................................................................................................................ Solid-state w/Magneto
Compression Ratio................................................................................................................................................................ 9.5:1
Starter................................................................................................................................................................................... 12 Vdc
Oil Capacity Including Filter........................................................................................................................................... Approx. 1.7 Qts.
Engine RPM / Alternator RPM....................................................................................................................................... 2,700 / 3600
Fuel Consumption
Natural Gas..............................................cu.ft./hr.
.................................................................1/2 Load.......................................................................................................... 115
................................................................Full Load.......................................................................................................... 202
Liquid Propane Gas...............................ft3/hr(gal/hr)
................................................................1/2 Load ..................................................................................................... 55.6 (1.52)
................................................................Full Load .................................................................................................... 86.4 (2.37)
CONTROLS Model 04916 (11kW)
Model Switch
-Auto ........................................................................................................................................................... Automatic Start on Utility
failure/7 day exerciser
-Off .......................................................................................................................................................... Stops unit. Power is removed
Control and charger still operate
-Manual/Test (start) ................................................................................................................................ Start with starter control, unit
stays on. If utility fails, transfer
to load takes place.
Engine Start Sequence Cyclic cranking: 7 sec. on, 7 rest
(90 sec. maximum duration)
Engine Warm-up .............................................................................................................................................................. 10 seconds
Engine Cool-Down ............................................................................................................................................................. 1 minute
Starter Lock-out ............................................................................................................................................... Starter cannot re-engage until
5 sec. after engine has stopped.
2.5 Amp Timed Trickle Battery Charger ............................................................................................................................ Standard
Automatic Voltage Regulator w/Overvoltage Protection .................................................................................................... Standard
Automatic Low Oil Pressure Shutdown ............................................................................................................................. Standard
Overspeed Shutdown .................................................................................................................................................. Standard, 72Hz
High Temperature Shutdown ............................................................................................................................................ Standard
Overcrank Protection ....................................................................................................................................................... Standard
Safety Fuse ..................................................................................................................................................................... Standard
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,
ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power
decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6° C (10° F) above 16° C (60°F).
Home Standby - 11kW
NOTE: The fuel system operates ONLY
on gaseous fuels.
Required fuel pressure:
Natural gas: 5 to 7 “ of water column
Liquid propane gas: 11 to 14” of
water column
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6° C (10° F) above 16° C (60°F).
FRONT VIEW 76.2 [3.00"]RIGHT SIDE VIEW REAR VIEW

AIR INTAKE
AIROUTLET 914mm [ 36.0" ]
914mm [ 36.0" ]
MINIMUM OPEN AREA
ALL AROUND UNIT
1219
[47.98"]
826
[32.54"]
SWING ARC OF SERVICE DOOR
1797 [70.76"] TOP VIEW
(WITH ROOF OPEN)
3/4" NPT FUEL INLET GAS PRESSURE OF
5-7" WATER COLUMN REQUIRED FOR NG FUEL,
ACCESS TO OUTPUT CIRCUIT 11-14" REQUIRED FOR LP FUEL
BREAKER AND TRANSFER SWITCH CONNECTIONS DO NOT LIFT BY THE ROOF
(REMOVE PLUG FOR ACCESS) 790 [31.09"] 468 [18.43"] GROUNDING LUG GROUNDING LUG 1219 [48.00"] 914 [36.00"] 457
LIFTING HOLES 4-CORNERS [18.00"] 76.2 [3.00"]
PEA GRAVEL
MINUMUM (SERVICE DOOR OPEN)
**ALL DIMENSIONS IN: MILLIMETERS [INCHES]
GENERAC POWER SYSTEMS |
All specifications are subject to change without notice.
Continuous Standby Power Rating Model 04916 -11kW LPG 60Hz 10kW NG 60Hz
Home