Generac Guardian Elite Commercial Generators - Buy Now Toll free
20-150 kW Liquid-Cooled Standby Generators and Controllers for Home or Office

Find generator sizes:  7 kW 10 kW 13 kW 20 kW up to 150 kW Single and Three Phase Commercial Generators

Revolutionizing the Commercial and Home Standby Power Generator Market

GUARDIAN® has long been known as America’s #1 choice in home standby generators. Now, we’re fast becoming recognized as the company that revolutionized the commercial market. That’s because we’ve eliminated the noise, fuel and installation concerns that traditionally made commercial standby power too costly. GUARDIAN Elite™ generators are reliable and value-oriented. So much so, they often pay for themselves during the first extended outage.

Single and Three Phase available in selected Generators.  See below for  information.

Generators
Features and Benefits
Spec Sheets
Controls and Transfer Switches

 

Commercial Standby Generators

20-150 kW Liquid-Cooled Standby Generators
Three Phase Generators for your Home or Business Power Needs *

GUARDIAN Elite 20-150 kW Liquid-Cooled Standby Generators
 
GUARDIAN® is now doing to the commercial market what it has already done to the residential market… making standby power reliable, yet affordable. Protect your revenue stream by investing in a GUARDIAN Elite™ commercial automatic standby generator. Our GUARDIAN Elite generators are ideal for a broad range of enterprises, including restaurants, convenience stores, supermarkets, banks, fitness centers, hotels, and retail outlets.

Three-phase models range from 20-150 kW and single-phase models from 60-150 kW. They run on either natural gas or LPV, feature automotive style, liquid-cooled engines, GUARDIAN’s exclusive Whisper-Test™ feature and a corrosion-resistant aluminum enclosure option. 

Whisper Quiet Operation
GUARDIAN’s exclusive patent-pending Whisper-Test low speed exercise feature makes our GUARDIAN Elite products the quietest liquid-cooled generators on the market. Whisper-Test reduces noise by 50% during the generator’s weekly self-test cycle allowing for near silent operation that satisfies all known sound ordinances. 

Value Priced
During a utility outage, a GUARDIAN Elite will protect your revenue stream and prevent expensive losses by keeping your business… in business. Not only are our products engineered for reliability and long life, our volume production and short lead times make GUARDIAN Elite products an even better value.
Generator Set
20-45 kW
60-80 kW
100-150 kW
Model Number QT02016 QT02516 QT03524 QT04524
Rated Power LP (kW) 20 25 35 45
Rated Power NG (kW) 20 25 35 43
Amps @ 208V, 3Ø 70 n/a 122 156
Amps @ 480V, 3Ø n/a n/a 53 68
Voltage @ 60 Hz 120/208 120/208 120/208, 277/480 120/208, 277/480
Phase Three Three Three Three
Frequency 60 Hz 60 Hz 60 Hz 60 Hz
Engine/Alternator RPM 3600/3600 3600/3600 3600/3600 3600/3600
Engine 1.6L OHC 4 cyl. 1.6L OHC 4 cyl. 2.4L OHC 4 cyl. 2.4L OHC 4 cyl.
Fuel Consumption LP
(cu.ft./hr.)/(gal./hr.)
125 (3.44) 175 (4.81) 222.3 (6.1) 286 (7.86)
Fuel Consumption NG (cu.ft./hr.) 315 437 560 720
EPA/CARB Certified Yes Yes Yes Yes
Fuel Natural Gas
LP Vapor
Natural Gas
LP Vapor
Natural Gas
LP Vapor
Natural Gas
LP Vapor
Engine Cooling Liquid Liquid Liquid Liquid
Controls R-Series R-Series R-Series R-Series
UL 2200 (US and Canada) Yes Yes Yes Yes
Sound Output dB(A) at 23 ft. with generator operating at full load 72 73 71 72
Sound Output dB(A) at 23 ft. with generator in WhisperTest™ low speed exercise mode 62 63 57 58
Main Line Circuit Breaker 80 Amp 100 Amp 150, 60 Amp 175, 80 Amp
Aluminum Enclosure Option Yes Yes Yes Yes
Dimensions (L" x W" x H") 71 x 29.5 x 36 71 x 29.5 x 36 77 x 33.5 x 45 77 x 33.5 x 45
Unit Wt. (lbs.) (steel/aluminum) 784/694 794/704 1393/1276 1414/1297

Generator Set
60-80 kW

Model # QT06030 QT07068 QT08046
Rated Power LP (kW) 60 70 80
Rated Power NG (kW) 60 70 80
Amps @ 240V, 1Ø 250 292 333
Amps @ 208V, 3Ø 208 243 278
Amps @ 480V, 3Ø 90 105 120
Voltage @ 60 Hz 120/240, 1Ø
120/208, 3Ø
277/480, 3Ø
120/240, 1Ø
120/208, 3Ø
277/480, 3Ø
120/240, 1Ø
120/208, 3Ø
277/480, 3Ø
Phase Single and 3-Phase Single and 3-Phase Single and 3-Phase
Frequency 60 Hz 60 Hz 60 Hz
Engine/Alternator RPM 3600/3600 1800/1800 3600/3600
Engine 3.0 V-6 6.8L V-10 4.6L V-8
Fuel Consumption LP
(cu.ft./hr.)/(gal./hr.)
376.3 (10.34) 411 (11.3) 465 (12.78)
Fuel Consumption NG (cu.ft./hr.) 960 1020 1154
EPA/CARB Certified Yes Yes Yes
Fuel Natural Gas
LP Vapor
Natural Gas
LP Vapor
Natural Gas
LP Vapor
Engine Cooling Liquid Liquid Liquid
Controls R-100 H-100 H-100
UL 2200 (US and Canada) Yes Yes Yes
Sound Output dB(A) at 23 ft. with generator operating at full load 73 71 74
Sound Output dB(A) at 23 ft. with generator in WhisperTest™ low speed exercise mode 62 60 61
Main Line Circuit Breaker 300, 250, 100 Amp 300, 250, 125 Amp 350, 300, 150 Amp
Aluminum Enclosure Option Yes Yes Yes
Dimensions (L" x W" x H") 88.6 x 33.5 x 47.8* 96.5 x 36.8 x 47.9 115.2 x 36.8 x 54.8*
Unit Wt. (lbs.) (steel/aluminum) 1650/1513 2185/2040 2010/1836

* Does not include measurement of exhaust stack(s)

Generator Set
100-150 kW
Model # QT10054 QT10068 QT13068 QT15068
Rated Power LP (kW) 100 100 130 150
Rated Power NG (kW) 100 100 130 150
Amps @ 240V, 1Ø 417 417 542 625
Amps @ 208V, 3Ø 347 347 451 520
Amps @ 480V, 3Ø 150 150 195 226
Voltage @ 60 Hz 120/240, 1Ø
120/208, 3Ø
277/480, 3Ø
120/240, 1Ø
120/208, 3Ø
277/480, 3Ø
120/240, 1Ø
120/208, 3Ø
277/480, 3Ø
120/240, 1Ø
120/208, 3Ø
277/480, 3Ø
Phase Single and
3-Phase
Single and
3-Phase
Single and
3-Phase
Single and
3-Phase
Frequency 60 Hz 60 Hz 60 Hz 60 Hz
Engine/Alternator RPM 3600/3600 2300/1800 3000/1800 3600/3600
Engine 5.4L V-8 6.8L V-10 6.8L V-10 6.8L V-10
Fuel Consumption LP
(cu.ft./hr.)/(gal./hr.)
554 (15.02) 507 (13.9) 719 (19.8) 830 (22.8)
Fuel Consumption NG (cu.ft./hr.) 1374 1260 1786 2061
EPA/CARB Certified Yes Yes Yes Yes
Fuel Natural Gas
LP Vapor
Natural Gas
LP Vapor
Natural Gas
LP Vapor
Natural Gas
LP Vapor
Engine Cooling Liquid Liquid Liquid Liquid
Controls H-100 H-100 H-100 H-100
UL 2200 (US and Canada) Yes Yes Yes Yes
Sound Output dB(A) at 23 ft. with generator operating at full load 75 74 74 76
Sound Output dB(A) at 23 ft. with generator in WhisperTest™ low speed exercise mode 62 61 61 62
Main Line Circuit Breaker 450, 400, 175 Amp 450, 400, 175 Amp 600, 500, 225 Amp 700, 600, 250 Amp
Aluminum Enclosure Option Yes Yes Yes Yes
Dimensions (L" x W" x H") 115.2 x 36.8 x 54.8* 115.2 x 36.8 x 54.8* 115.2 x 36.8 x 54.8* 115.2 x 36.8 x 54.8*
Unit Wt. (lbs.) (steel/aluminum) 2311/2137 2705/2531 2873/2699 2666/2492

* Does not include measurement of exhaust stack(s)

Controls and Transfer Switch

R-Series Digital Controller
H-100 Digital Controller
Transfer Switch
7 LED Indicator Lights Standard
High Temperature Shutdown Standard
Low Coolant Level Shutdown Standard
Automatic Voltage Regulator with Over-voltage Protection Standard
  • Voltage Regulation (at steady state from no load to 100% load
± 1.0 %
  • Frequency Regulation (at steady state from no load to 100% load)
± 0.5%
Engine Start Sequence Cyclic Cranking: Initially 15 sec. on, then 7 sec. rest, 7 sec. on. 90 sec. maximum duration
Safety Fuse Standard
Starter Lockout Starter cannot re-engage until 5 sec. after engine has stopped
2 Amp Battery Charger Standard
Engine Warm-up 10-15 seconds
Engine Cool-down 1 minute
Mode Switch
  • Auto Position
Utility Failure / 7 day exerciser
  • Off Position
Stops unit. Power is removed. Control and charger still operate.
  • Manual/Test Position
Start with starter control, unit stays on. If utility fails, transfer to load takes place
Automatic Weekly Exerciser with Selectable Low Speed Exercise Standard
Controls and Transfer Switch
H-100 Digital Controller
32-Bit Microprocessor Single point of control for engine, generator and transfer switch functions
Automatic Voltage Regulator with Over-voltage Protection Standard
  • Variable Voltage Frequency Settings
Allows matching V/F to load for more consistent output; prevents excessive engine lugging under load to protect motors and improve motor starting
  • Voltage Regulation (at steady state from no load to 100% load)
± 0.25%
  • Frequency Regulation (at steady state from no load to 100% load)
Isochronous
Sealed Casing Protects against vibration, dust, heat moisture, corrosion, radio interference, electromagnetic interference and static discharge
Low Coolant, Hight Temperature and Low Oil Pressure Automatic Shutdown Standard
Digital Readout of AC kW, kVA, Power Factor and All Engine Functions Standard
Isochronous Govenor Control Standard
Predictive Maintenance Reminders Standard
3 Phase Sensing Protects motor by monitoring voltage across all 3 phases
2 Amp Automatic Battery Charger Standard
Fault Protection (I2T Function) Provides total generator winding protection under all fault conditions
Start/Stop Control Programmable auto-crank feature
Starter Lockout Standard
Automatic Weekly Exerciser with Selectable Low Speed Exercise Standard
Overspeed/Over-voltate Protection Standard
Overcrank Protection Standard
Emergency Stop Standard
RS485 Remote 2-way Communication with HTS Transfer Switch Standard
RS232 & RS485 Outputs Computer connections for remote monitoring and remote adjustments (with optional model and GenLink software)
Controls and Transfer Switch
Transfer Switch
Liquid-cooled models with 3.0 liter engines or smaller use RTS transfer switches (100-400 amps).
Liquid-cooled models with engines over 3.0 liters use HTS transfer switches (100-800 amps).
For more information please see the Transfer Switch page.

Features and Benefits

Automotive Engine
GUARDIAN Elite™ generators use modified automotive engines that can easily be serviced using readily available, cost-effective parts. These engines are produced in high volume allowing to pass along the cost savings to our customers.

Whisper-Test™
Reduces noise to a whisper by lowering engine speed during the generator’s weekly self-test. The Whisper-Test sound level is comparable to a car at idle and is 50% quieter than the competition.

Superior Paint
New textured, powder coat paint process provides consistent coverage and better bonding to seams and exposed edges. This ensures greater durability and a longer lasting finish.

Aluminum Enclosure
GUARDIAN Elite generators are available in a corrosion-resistant aluminum enclosure to better withstand the elements. This option is especially important for businesses in southern and coastal communities.

Automatic Exerciser
An automatic seven (7) day test of your system allows you to verify that your generator is in peak operating condition at all times.

Automatic Transfer Switch
The automatic transfer switch automatiy switches the source of power from utility to the generator within seconds of a power outage. Because it’s automatic, you never have to flip a switch.

Convenient Fuel Supply
GUARDIAN Elite generators operate on natural gas or LP gas service. This provides you with unlimited run time during extended utility power failures.

Maintenance Friendly
GUARDIAN Elite generators feature large, removable doors. This provides easy and quick access for servicing and maintenance.

Automatic Safety Shutdowns
Automatic safety shutdowns protect the engine and generator in the event of low oil pressure, high temperature, overspeed and/or overcrank.

Protective Enclosure
The enclosure protects your generator from harmful weather and includes key locks for security. Sound-absorbing panels also reduce exterior noise levels.

Battery Charger
A built-in battery charger ensures that the battery remains at an optimum performance level.

UL-Listed
For your safety, GUARDIAN standby generators are UL 2200 listed and all transfer switches are UL 1008 listed. This validates safety and kilowatt ratings.

EPA and CARB Emission Requirements
Generators up to 25kW must comply with EPA and CARB emissions requirements. All GUARDIAN generators up to 25 kW meet these requirements.

Made in USA
Manufactured by Generac Power Systems, we design and build our complete product from the controls to the enclosures. This ensures that all GUARDIAN Elite products are built to our highest standards.

GUARDIAN Elite™ Spec Sheets

Generators
20kW - 1.6L
25kW - 1.6L
35kW - 2.4L
45kW - 2.4L
60kW - 3.0L
70kW - 6.8L
80kW - 4.6L
100kW - 5.4L
100kW - 6.8L
130kW - 6.8L
150kW - 6.8L

GUARDIAN Elite™ Spec Sheets

Transfer Switches

RTS Automatic Transfer Switch
HTS Automatic Transfer Switch


Control Panels
R-Series Control Panel, 20kW thru 60kW
H-100 Control Panel, 70kW - 6.8L thru 150kW

GUARDIAN spec sheets are available to download as Adobe Acrobat PDF files. Click on the PDF link to view the document.
Get Adobe Reader


Shipping cost may be extra - for shipping quote and ship time *Cash discount for wire transfer

* Cash discount for wire transfer
** Delivery time may be up to 8 weeks during natural disasters.  Plan ahead for Hurricane Season!!

 Transfer Switches  |  Generator Control Panel  |  Home

Commercial single phase and commercial three (3) Phase Rated Amps at 120/208V, 0.8pf Generac Guardian Elite Models 

Copyright 2005 Best Generators | Legal Notices

Copyright 2006 Power Generators